Analysis of possible problems during the installation process of card sleeve connectors

Home » Analysis of possible problems during the installation process of card sleeve connectors

● Installation

1. Cut off seamless steel pipes of appropriate length and remove burrs at the ends. The end face of the pipe should be perpendicular to the axis, with an angle tolerance of no more than 0.5 °. If the pipe needs to be bent, the length of the straight section from the end face of the pipe to the bent part must not be less than three times the length of the nut.

Two nuts and clamps are fitted onto the seamless steel pipe. Pay attention to the direction of the nut and sleeve, and do not install them upside down.

Apply lubricating oil to the threads and sleeve of the pre assembled joint body, insert the pipe into the joint body (make sure the pipe is inserted to the bottom), and tighten the nut by hand.

Tighten the nut until the sleeve grips the pipe, and this turning point can be felt by increasing the tightening torque (pressure point).

After reaching the pressure point, tighten the compression nut by 1/2 turn.

6. Remove the pre assembled joint body and check the embedding of the blade edge of the card sleeve. The visible protrusion must fill the space on the end face of the card sleeve. The card sleeve can rotate slightly, but cannot move axially.

7. For final installation, apply lubricating oil to the threads of the joint body during actual installation, tighten the nuts and tighten them until the noticeable tightening force increases Then tighten another 1/2 turn to complete the installation.

● Repeated installation

All card sleeve connectors can be reinstalled multiple times, but it is important to ensure that the parts are undamaged and clean.

Insert the pipe into the joint body until the sleeve fits snugly against the conical surface of the joint body, and tighten the nut by hand.

Tighten the nut with a wrench until the tightening torque increases sharply, then tighten it by 1/4 to 1/2 turn.

● Inspection

Disassemble the pipe to check if the assembly meets the requirements: there should be a uniform slight protrusion on the pipe at the end of the sleeve. The card sleeve cannot slide back and forth, but slight rotation is allowed.

● Reasons for leakage

The pipe is not fully inserted.

The two nuts are not tightened.